Follett Ice Machine LED Indicator & Error Code Guide
Complete troubleshooting reference for all Follett Chewblet ice machine LED indicators, hard and soft errors, and maintenance procedures. Covers Symphony Plus, 7 Series, 15 Series, Horizon Elite, and Maestro Plus models. Houston service available 24/7.
Follett LLC is a subsidiary of The Middleby Corporation
Healthcare Facility Notice
The Joint Commission standard EC.02.05.01 requires healthcare facilities to develop a written maintenance strategy based on manufacturer recommendations. Follett recommends semi-annual (every 6 months) cleaning and sanitization. Document all service activities for compliance audits.
LED Indicator Quick Reference — All Models
Maintenance
6-month periodic maintenance due
RED — Timer-BasedLow Water
Water supply issue detected
YELLOW — Check SupplyTime Delay
Ice jam in transport tube
YELLOW — Timed DelaySleep Cycle
Machine in sleep mode
YELLOW — NormalMaking Ice
Normal ice production active
GREEN — NormalLow Bin
Storage bin is low on ice
GREEN — InformationalPower On
Machine has power
GREEN — NormalHard Errors vs. Soft Errors
Hard Errors
Require pressing the physical reset button on the control board inside the machine.
Power cycling will NOT clear a hard error. You must open the machine and press reset.
Soft Errors
Machine shuts down for approximately 1 hour, then automatically retries.
If the underlying issue is resolved, a soft error clears on its own without intervention.
Additional Indicators — Maestro Plus & Horizon Elite
These indicators appear on Horizon Elite (710, 1010, 1410 series) and Maestro Plus (MCD425A/W) models.
HI PRESSURE
Clogged condenser on air-cooled models. Condenser coils need cleaning.
Hard Error — Requires manual resetHI AMPS
Auger gearmotor exceeding 0.55A. Caused by jammed auger, scale buildup, or bad water quality.
Hard Error — Requires manual resetDRAIN CLOG
Drain pan water backup detected. Check drain line for obstructions.
Check drain line and pan20M / 2nd LED (Torque Error)
Machine runs briefly then shuts down. Indicates a torque overload on the auger motor.
Typically requires professional serviceRed Maintenance Light: 6-Month Service Due
Timer-based indicator — not a fault or failure
What This Means
6-Month Timer Expired
Follett machines have a built-in 6-month countdown timer. When it reaches zero, the red Maintenance LED activates to signal that periodic cleaning and sanitization is due.
This Is Follett's Recommended Interval
Semi-annual cleaning aligns with Follett's published maintenance schedule. In Houston, hard water may warrant attention sooner.
Resolution Steps
Clean with SafeCLEAN
Use Follett SafeCLEAN (P/N 00132001) or SafeCLEAN Plus (P/N 01147826). Mix 7 oz with 1 gallon of 120°F water. Never use bleach.
Sanitize with Nu-Calgon IMS-II
Use Nu-Calgon IMS-II Sanitizer (P/N 00979674) at 1.6 oz per gallon of 120°F water.
Enter Maintenance Mode & Reset
Press and hold the maintenance/clean switch for 5 seconds to enter maintenance mode and reset the 6-month timer.
Call a pro if: You are unsure of the cleaning procedure or need compliance documentation for a healthcare facility. Service call: $150-$400.
Yellow Low Water Light: Water Supply Issue
Machine cannot detect adequate water supply
Common Causes
Water Supply Valve Closed
The supply valve behind or under the machine may have been turned off during other maintenance.
Kinked or Blocked Water Line
Check the supply line for kinks, especially if the machine was recently moved.
Clogged Inlet Filter or Screen
Houston's hard water (300+ ppm TDS) can deposit sediment that clogs the inlet filter over time.
Low Building Water Pressure
Insufficient supply pressure prevents the machine from filling properly.
Very Pure Water (Below 10 ppm TDS)
Follett machines require a minimum 10 ppm TDS for the conductivity sensor to detect water. Facilities using RO or DI water may trigger false Low Water errors.
Resolution Steps
Verify Water Supply (DIY)
Confirm the supply valve is fully open and the water line is not kinked or pinched.
Inspect Inlet Screen (DIY)
Clean or replace the inlet screen/filter if sediment is visible. Houston water is particularly prone to sediment buildup.
Check Water Quality
If your facility uses RO or very soft water, test TDS levels. Water below 10 ppm TDS will cause false Low Water readings.
Call a pro if: Water supply checks out but the light persists — the water inlet valve or conductivity sensor may need replacement.
Yellow Time Delay Light: Ice Jam or Timed Delay
Ice jam in transport tube or machine in timed delay cycle
What Triggers This Light
Ice Jam in Transport Tube
Ice has jammed in the transport mechanism between the evaporator and the storage bin. The machine pauses to let ice melt and clear.
Timed Delay Between Cycles
Normal operational pause between ice production cycles. The machine will resume automatically.
Resolution Steps
Wait for Automatic Clearing
In most cases, the machine resolves this on its own. Allow up to 30 minutes for the delay cycle to complete.
Check Bin Level
If the bin is overfull, dispense or remove some ice to allow the transport tube to clear.
Call a pro if: Time Delay light activates repeatedly — may indicate scale buildup in the transport tube or a failing auger motor.
HI PRESSURE & HI AMPS: Larger Model Errors
Hard errors on Horizon Elite and Maestro Plus — require manual reset
HI PRESSURE — Clogged Condenser
Air-Cooled Models Only
The condenser coils are clogged with dust, grease, or debris, causing refrigerant pressure to exceed safe limits.
Resolution
- 1. Power off the machine
- 2. Clean condenser coils thoroughly (vacuum and brush)
- 3. Ensure adequate ventilation clearance around the unit
- 4. Press the reset button on the control board (power cycling alone will not clear this)
HI AMPS — Auger Motor Overload
Gearmotor Exceeding 0.55A
The auger motor is drawing excessive current. Common causes: jammed auger from scale buildup, foreign object, or worn bearings.
Resolution
- 1. Power off and inspect the auger for jams or scale
- 2. Descale the evaporator cylinder with SafeCLEAN
- 3. Check incoming water quality (Houston hard water accelerates scale)
- 4. Press the reset button on the control board after clearing the issue
Professional service recommended. HI AMPS errors often indicate significant scale buildup or mechanical wear that requires specialized tools. Est. cost: $150-$400.
Filter Replacement & Reset Procedure
DIY-friendly — correct filter part numbers and 10-second reset
Healthcare Priority: In hospital and clinical settings, filter replacement is essential for patient safety. Use only Follett-approved filter cartridges to maintain warranty and compliance.
Approved Filter Part Numbers
| Part Number | Capacity | Compatible Models |
|---|---|---|
| 00130229 | Standard system (3,000 gal) | Maestro Plus, Symphony Plus |
| 00968107 | Standard cartridge | 7 Series, 15 Series |
| 00978957 | High Capacity (15,000 gal) | All models |
Filter Replacement Steps
Get the Correct Filter
Match the part number to your model using the table above. Generic filters may void warranty and compromise water quality.
Replace the Filter
Turn off water supply, swap the filter cartridge, then flush 2 gallons through the new filter before returning to service.
Reset Filter Timer (10 Seconds)
Remove the front panel to access the control board. Press and hold the filter reset button for 10 seconds until the indicator clears. This button is inside the machine, not on the exterior.
Houston Water Quality Note
Houston municipal water averages 300+ ppm TDS (hard water). This means filters may reach capacity before the timer expires. If you notice reduced ice production or cloudy ice before the filter indicator activates, replace the filter early.
Consider the high-capacity filter (P/N 00978957, 15,000 gal) for high-volume Houston facilities.
This is DIY-friendly. Filter replacement costs $50-$120 for the cartridge. Contact professional service only if the indicator will not reset after replacement.
Healthcare Ice Machine Specialists
Our technicians are experienced with all Follett models in Houston hospitals, clinics, and care facilities. We provide Joint Commission compliance documentation with every service visit.
Approved Cleaning Products for Follett Machines
SafeCLEAN / SafeCLEAN Plus (Cleaner)
- Part Numbers: 00132001 / 01147826
- Mix Ratio: 7 oz per 1 gallon of 120°F water
- Follett's proprietary cleaner — specifically formulated for Chewblet evaporators
Nu-Calgon IMS-II (Sanitizer)
- Part Number: 00979674
- Mix Ratio: 1.6 oz per 1 gallon of 120°F water
- Approved sanitizer for all Follett models
Never Use These on Follett Equipment
Follett Product Lines We Service in Houston
Symphony Plus
12, 25, 50, 110 Series
Up to 425 lb/day production
7 Series
Countertop dispenser
125 lbs/day, 7 lbs storage
15 Series
Extended storage countertop
Up to 100 lbs/day, 15 lbs storage
Horizon Elite
710, 1010, 1410 Series
High-capacity floor models
Maestro Plus
MCD425A/W
Separate icemaking module
All models produce Follett's signature Chewblet™ soft, chewable nugget ice preferred in healthcare settings.
Follett Maintenance Schedule for Houston Facilities
Houston Water Quality Impact
Houston's municipal water averages 300+ ppm total dissolved solids, which is classified as hard water. This accelerates scale buildup and filter clogging. While Follett's standard maintenance interval is semi-annual (6 months), Houston facilities should monitor conditions and consider more frequent descaling if ice quality degrades.
Weekly
- Visual inspection of dispensing area
- Wipe down exterior surfaces
- Check for unusual sounds or ice quality changes
- Verify all LED indicators are normal (green)
Monthly
- Deep clean dispensing area
- Inspect water filter condition
- Check drain for blockages
- Clean condenser coils (air-cooled models)
Semi-Annual (6 Months)
- Full cleaning with SafeCLEAN
- Sanitization with Nu-Calgon IMS-II
- Replace water filter
- Professional descaling (recommended for Houston)
- Reset maintenance timer
- Document for Joint Commission compliance
Joint Commission Compliance: Standard EC.02.05.01 requires a written maintenance strategy based on manufacturer recommendations. Follett's recommendation is semi-annual service. Your facility's maintenance plan should reflect this interval, adjusted for local water conditions and usage volume.
Follett Technical Support
Phone: (877) 612-5086
Hours: Mon-Fri, 8am-5pm ET
After-Hours Emergency: Available until 8pm ET
For local Houston service with faster response times and on-site support, book with us below.
Follett Healthcare Dispenser Experts in Houston
Full-service maintenance for Symphony Plus, 7 Series, 15 Series, Horizon Elite, and Maestro Plus across Houston medical facilities
Need Follett Service in Houston?
From filter replacements to full sanitization with FDA-compliant sanitizers, we keep Follett Chewblet dispensers running clean in hospitals, clinics, and care facilities across Houston.
FDA-compliant sanitizers | Joint Commission documentation | 2-hour emergency response | All Follett models serviced